Research and Preliminary Application of a Rapid Immunoassay Method for Eugenol Based on Quantum Dots
CSTR:
Author:
Affiliation:

1.Institute of Sea Food, Zhejiang Gongshang University, Hangzhou 310012, China;2.Hangzhou Bioeast Biotech Co., Ltd., Hangzhou 310018, China;3.Hangzhou Nankai Biotech Co., Ltd., Hangzhou 310051, China

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    [Objective]This study aims to establish a rapid immunoassay method for the quantitative detection of eugenol.[Method]The eugenol monoclonal antibody was conjugated to the surface of quantum dots by the 1-ethyl-3- (3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy-succinamide (NHS) (EDC-NHS) coupling method, with quantum dots as fluorescent markers. Bovine serum albumin (BSA) was used for blocking, and fluorescence microscopy, agarose gel electrophoresis, and a microplate reader were used for identification. Furthermore, the established method was compared with high performance liquid chromatography (HPLC).[Result]The optimal synthesis conditions were as follows: quantum dot activation time of 30 min, conjugation pH with 8.0, antibody addition of 21 μL, and conjugation incubation time of 3.0 h. The optimal buffer system was as follows: carbonate buffered solution (CBS) with the coating buffer solution of 0.05 mol/L and pH 9.6, phosphate buffered solution (PBS) with the quantum dots-monoclonal antibody (QDs-mAb) concentration of 0.01 mol/L and pH 7.4. The quantum dots-fluorescence immunoassay (QDs-FIA) method was established under optimized conditions, with the linear equation of y=13.098ln x+9.625 8, R2=0.993 1. The IC20, IC50, and IC80 were 2.21, 21.81, and 215.49 ng/mL, respectively. Recovery test were performed on water samples and bass meat samples, with recovery rate ranging from 96.32% to 103.01% for water samples and 94.16%~102.28% for bass meat samples, and the coefficients of variation were less than 7%.[Conclusion]The established QDs-FIA method has good sensitivity and accuracy, which can provide a theoretical basis for the development of fluorescent assay kit in the future.

    Reference
    Related
    Cited by
Get Citation

SUN Junjie, LIU Xiaoxia, CHEN Ziyi, LI Yinlai, ZHAI Lu, CHEN Qinzhou, JIN Renyao. Research and Preliminary Application of a Rapid Immunoassay Method for Eugenol Based on Quantum Dots[J]. Journal of Food Science and Biotechnology,2025,44(7):137-148.

Copy
Related Videos

Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:November 26,2024
  • Revised:January 03,2025
  • Adopted:
  • Online: November 03,2025
  • Published:
Article QR Code

Copy Right:Editorial Board of Journal of Food Science and Biotechnology

Address:No. 1800, Lihu Avenue, Wuxi 214122, Jiangsu Province,China  PostCode:214122

Phone:0510-85913526  E-mail:xbbjb@jiangnan.edu.cn

Supported by:Beijing E-Tiller Technology Development Co., Ltd.

WeChat

Mobile website